167 Worked Example: Smart Building Architecture Mapping
167.1 Learning Objectives
By the end of this chapter, you will be able to:
- Map real-world systems to the 7-layer IoT reference model systematically
- Calculate data volumes and storage requirements for IoT deployments
- Design layer-appropriate APIs that abstract underlying complexity
- Create complete architecture documentation ready for implementation
167.2 Introduction
This worked example walks through the complete process of mapping a commercial building IoT system to the Cisco 7-layer reference model. Follow along step-by-step to understand how architectural decisions are made at each layer.
The scenario represents a common enterprise IoT deployment with multiple sensor types, real-time control requirements, and long-term data retention needs.
A worked example shows the complete solution process, not just the final answer. Like watching a chef prepare a dish step-by-step, you’ll see:
- The problem statement - What we’re trying to build
- The analysis process - How we break down requirements
- Design decisions - Why we choose specific technologies
- The complete solution - All layers documented
This is how real architects approach IoT system design.
167.3 Worked Example: Mapping a Smart Building System
Scenario: You are architecting an IoT system for a commercial office building with 500 occupancy sensors, 200 HVAC control units, and 50 energy meters. The building manager wants a dashboard showing real-time occupancy, automated climate control, and monthly energy reports. Map this system to the Cisco 7-layer reference model.
Given Requirements:
- 750 total sensors/actuators across 15 floors
- Requirement: <2 second response for HVAC adjustments based on occupancy
- Data retention: 2 years of historical data for energy compliance reporting
- Users: Building manager, maintenance team, energy consultants (external)
167.3.1 Step 1: Identify Layer 1 (Physical Devices)
The first step is to inventory all physical devices and understand their data characteristics.
Device Inventory:
| Device Type | Count | Data Rate | Protocol | Output |
|---|---|---|---|---|
| Occupancy (PIR) | 500 | 1 Hz (motion events) | Zigbee | Boolean + timestamp |
| HVAC controllers | 200 | 0.1 Hz (setpoint changes) | BACnet | Temperature, fan speed |
| Energy meters | 50 | 1 Hz (power readings) | Modbus | kW, kWh, power factor |
Data Volume Calculation:
Peak readings = 500 + (200 x 0.1) + 50 = 570 readings/second average
Peak with simultaneous events = 751 readings/second
Layer 1 Result: The perception layer generates approximately 570-751 readings/second at peak.
Why different protocols for different devices?
- Zigbee for occupancy: Battery-powered devices need low-power mesh networking
- BACnet for HVAC: Industry standard, existing building infrastructure uses it
- Modbus for meters: Simple, reliable, meters are wired anyway
167.3.2 Step 2: Design Layer 2 (Connectivity)
Layer 2 handles protocol translation and network topology.
Network Architecture:
Protocol Stack:
- Zigbee mesh for 500 occupancy sensors (low power, self-healing)
- BACnet/IP for HVAC (industry standard, existing infrastructure)
- Modbus TCP for energy meters (reliable, simple)
- MQTT broker at each floor aggregating all protocols
Key Design Decision: Protocol translation happens at the Layer 2/3 boundary via floor-level gateways. Each floor has its own MQTT broker, reducing inter-floor traffic and providing local redundancy.
167.3.3 Step 3: Design Layer 3 (Edge Computing)
Layer 3 determines what processing happens locally versus in the cloud.
Processing Location Analysis:
| Processing Task | Location | Latency Requirement | Rationale |
|---|---|---|---|
| Occupancy to HVAC trigger | Floor gateway | <2 sec | Real-time control loop |
| Energy spike detection | Floor gateway | <5 sec | Immediate alerts |
| Data aggregation (5-min rollups) | Floor gateway | N/A | Reduce cloud bandwidth |
| ML occupancy prediction | Cloud | Minutes | Requires historical data |
Edge Hardware Selection:
Each floor has a Raspberry Pi 4 gateway running:
- Node-RED: Local rule engine for real-time HVAC control
- Mosquitto: MQTT broker for floor-level aggregation
- InfluxDB (edge instance): 24-hour local buffer
Critical Insight: The <2 second HVAC response requirement forces occupancy-to-HVAC logic into Layer 3. If this went through the cloud, network latency alone (200-500ms round-trip) plus processing time would risk exceeding the 2-second SLA.
A naive design might route all data through the cloud for simplicity. This would:
- Add 200-500ms latency (cloud round-trip)
- Fail the <2 second requirement during network congestion
- Stop working entirely during internet outages
Edge processing at Layer 3 solves all three issues.
167.3.4 Step 4: Design Layer 4 (Data Accumulation)
Layer 4 selects storage systems for different data types.
Storage Architecture:
| Data Type | Storage System | Retention | Access Pattern |
|---|---|---|---|
| Sensor readings | InfluxDB (time-series) | 30 days raw, 2 years aggregated | Time-range queries |
| Device metadata | PostgreSQL (relational) | Permanent | Key-value lookups |
| Configuration | PostgreSQL | Permanent | Infrequent reads |
| Compliance archive | S3/Glacier | 2+ years | Rare access, regulatory |
Capacity Planning:
Daily data volume:
= 751 readings/sec x 86,400 sec x 100 bytes/reading
= 6.5 GB/day raw
Storage requirements:
- 30-day raw: 195 GB
- 2-year aggregated (1-min resolution): ~700 GB
- Total with overhead: ~1 TB active + 4.7 TB archive
Data Lifecycle:
- Hot (0-7 days): Full resolution in InfluxDB, SSD storage
- Warm (7-30 days): Full resolution, HDD storage
- Cold (30 days - 2 years): 5-minute aggregates in S3
- Archive (2+ years): Glacier for compliance
167.3.5 Step 5: Design Layer 5 (Data Abstraction)
Layer 5 creates unified APIs that hide storage complexity from applications.
API Design:
# Current occupancy - queries InfluxDB
GET /api/v1/floors/{id}/occupancy/current
Response: { "floor": 5, "occupied_zones": 12, "total_zones": 20, "percentage": 60 }
# Historical energy - queries S3 archive
GET /api/v1/energy/report?start=2024-01&end=2024-12
Response: { "monthly_kwh": [...], "cost_breakdown": {...} }
# Device metadata - queries PostgreSQL
GET /api/v1/devices/{device_id}
Response: { "type": "occupancy", "floor": 5, "zone": "A", "last_seen": "..." }
Key Abstraction Benefit: The API consumer doesn’t know that:
- Current occupancy comes from InfluxDB
- Historical reports come from S3 archives
- Device metadata comes from PostgreSQL
Adding a new storage backend (e.g., moving to TimescaleDB) requires zero application changes.
167.3.6 Step 6: Design Layer 6 (Application)
Layer 6 builds user-facing applications.
Application Portfolio:
| Application | Users | Key Features |
|---|---|---|
| Operations Dashboard | Building manager | Real-time floor maps, HVAC override controls |
| Mobile Alerts App | Maintenance team | Push notifications for equipment faults |
| Energy Portal | External consultants | Monthly reports, trend analysis, compliance docs |
Technology Stack:
- Dashboard: React + Grafana for real-time visualization
- Mobile App: React Native for cross-platform
- Energy Portal: Django with scheduled report generation
167.3.7 Step 7: Design Layer 7 (Collaboration)
Layer 7 defines business processes triggered by IoT data.
Automated Workflows:
- Energy Alert Workflow:
- Trigger: Energy consumption > 120% of baseline
- Action: Email to facilities manager
- Escalation: Work order in CMMS if not acknowledged in 4 hours
- HVAC Failure Workflow:
- Trigger: Temperature drift > 5F from setpoint for 30+ minutes
- Action: Immediate page to on-call technician
- Escalation: If unresolved in 30 min, escalate to HVAC contractor
- Monthly Review Process:
- Trigger: First business day of month
- Action: Energy consultant receives automated report
- Outcome: Schedules optimization review with building manager
167.4 Complete Architecture Summary
%%{init: {'theme': 'base', 'themeVariables': { 'primaryColor': '#2C3E50', 'primaryTextColor': '#fff', 'primaryBorderColor': '#16A085', 'lineColor': '#16A085', 'secondaryColor': '#E67E22', 'tertiaryColor': '#7F8C8D'}}}%%
graph TB
subgraph L7["Layer 7: Collaboration"]
WF["Workflows & Escalations"]
end
subgraph L6["Layer 6: Application"]
DASH["Dashboard"]
MOB["Mobile App"]
PORT["Portal"]
end
subgraph L5["Layer 5: Abstraction"]
API["REST API Gateway"]
end
subgraph L4["Layer 4: Accumulation"]
TS["InfluxDB"]
SQL["PostgreSQL"]
S3["S3/Glacier"]
end
subgraph L3["Layer 3: Edge"]
EDGE["Floor Gateways<br/>(Node-RED + MQTT)"]
end
subgraph L2["Layer 2: Connectivity"]
NET["Zigbee + BACnet + Modbus"]
end
subgraph L1["Layer 1: Physical"]
DEV["500 Sensors + 200 HVAC + 50 Meters"]
end
DEV --> NET --> EDGE --> TS & SQL
TS & SQL & S3 --> API --> DASH & MOB & PORT --> WF
style L1 fill:#16A085,stroke:#2C3E50,color:#fff
style L3 fill:#E67E22,stroke:#2C3E50,color:#fff
style L5 fill:#2C3E50,stroke:#16A085,color:#fff
style L7 fill:#2C3E50,stroke:#16A085,color:#fff
Architecture Summary Table:
| Layer | Components | Key Technology |
|---|---|---|
| 7 - Collaboration | Workflows, escalations, reviews | Slack, ServiceNow, Email |
| 6 - Application | Dashboard, mobile app, portal | React, React Native, Grafana |
| 5 - Abstraction | REST APIs, data federation | Node.js API, GraphQL |
| 4 - Accumulation | Time-series, relational, archive | InfluxDB, PostgreSQL, S3 |
| 3 - Edge | Local rules, aggregation | Raspberry Pi, Node-RED |
| 2 - Connectivity | Protocol translation, routing | MQTT, Zigbee, BACnet gateway |
| 1 - Physical | Sensors, actuators | PIR, thermostats, meters |
167.5 Key Insights from This Exercise
The 7-layer analysis revealed that the <2 second HVAC response requirement forces occupancy-to-HVAC logic into Layer 3 (edge), not Layer 6 (cloud application).
Without this layered analysis, a naive design might route all data through the cloud, adding 200-500ms latency and failing the requirement.
Other Insights:
- Data volume planning at Layer 1 informs storage decisions at Layer 4
- Latency requirements determine the edge/cloud processing split at Layer 3
- API abstraction at Layer 5 enables future storage technology changes
- Workflow automation at Layer 7 closes the loop from data to action
167.6 Practice Exercise
Apply the same 7-layer mapping process to this scenario:
Requirements:
- 200 patient monitors (heart rate, SpO2, blood pressure)
- 50 medication dispensers (automated dosing)
- Real-time alerts to nursing stations (<1 second for critical vitals)
- 7-year data retention (HIPAA compliance)
- Integration with existing Electronic Health Record (EHR) system
Questions to Answer:
- What devices go in Layer 1? What protocols?
- Where does the <1 second alert requirement force processing?
- What storage strategy supports 7-year retention?
- How does Layer 5 integrate with the existing EHR?
167.7 Summary
This worked example demonstrated the systematic process for mapping an IoT system to the 7-layer reference model:
- Layer 1: Inventory devices and calculate data volumes
- Layer 2: Design protocol translation and network topology
- Layer 3: Determine edge vs cloud processing based on latency requirements
- Layer 4: Select storage systems matching data characteristics and retention needs
- Layer 5: Design abstraction APIs that hide storage complexity
- Layer 6: Build user-appropriate applications
- Layer 7: Define automated workflows for human collaboration
The key takeaway is that reference models are practical tools, not just theoretical frameworks. They reveal requirements (like edge processing needs) that might otherwise be missed.
167.8 What’s Next
Continue with practical application:
- Interactive Quiz and Game - Test your understanding with auto-grading assessments
- Hands-On Lab - Build a working multi-layer IoT demo with ESP32