11.1 Modules Hide Circuit Choices
The TP4056 breakout in Figure 2 exposes the connections that a module choice can hide.
The Micro-USB socket is the board’s input connector, while the B+ and B- pads are marked for the battery and OUT+ and OUT- for the output path. The photo also shows status LEDs and other support parts around the charger IC. Those visible parts matter when moving from a breakout to a PCB: copying only the chip would omit circuit choices already made on the module. Record which connector and pads were used in the prototype, and identify the protection and support circuit from the module documentation before redrawing the circuit. The photograph helps locate parts; it does not prove their ratings or wiring by itself.
Before replacing the module, trace the support circuits that produce its behavior.
- Find the Micro-USB input and charger IC in the photo. Use the exact board’s documentation to trace the connection from the input to the charger.
- Locate the battery pads (B+ and B-) and load pads (OUT+ and OUT-). On the same documentation, mark where the battery connects, where the protection circuit sits, and how power reaches the load pads.
- If you also sketch a separate design with a dedicated load-sharing path, label it as a separate design and mark where that path supplies the load.

Technical detail
Support circuits behind a module
Trace pull-ups, level shifting, and signal conditioning before moving to a PCB.

Technical detail
Power paths and actuator defaults
Check charger behavior, rail disturbances, and driver states hidden by ready-made boards.
11.2 Parallel Pull-ups and Antenna Gain
The greenhouse bus and radio each need a numerical margin check. Keep the assumptions with the result so a board or antenna change triggers a fresh review.

Technical detail
Parallel pull-ups and directional antenna gain
Calculate sink-current margin and EIRP under stated assumptions.

Maths · guided foundations
Maths
Voltage Vera combines parallel pull-ups, LOW-level current, sink margin, and antenna gain in one component ledger. Work out the current when a device pulls the bus low, compare it with the device rating, and trace antenna gain through a link budget. Record the assumptions so a board or antenna change prompts a fresh check.

Knowledge check · self-test
Check: Component selection evidence
Check bench acceptance, cable faults, module support circuits, and radio field evidence.
11.3 Sensor Selection
A sensor turns a physical condition into an electrical signal. Choose one that fits the range and conditions of the actual task. Test its output against a known reference. Save the raw readings so another person can check the choice.
Review sensors across five evidence lanes before wiring them into a prototype.
Signal termination uses a component at a line end, often a resistor, to match the line and reduce reflected signals. Check whether the interface and cable need it, and use the value and placement required by that interface.
Inspect Figure 3 and ask which of the five evidence lanes could disqualify an otherwise familiar sensor.
Read Figure 3 across its five lanes. Measurement fit checks range, resolution, accuracy, response, drift, and repeat use. Site fit covers heat, water, dust, shock, light, and mounting. Interface fit states the address, pins, timing, cable, and line end. Power fit checks active current, idle state, warm-up, and duty cycle. The last lane links a reference method and later checks to the move from raw values into units. A popular part still fails the review if proof is missing from any lane.
Measurement fit. Range, resolution, accuracy class, response time, drift, and repeatability should match the decision the system will make from the reading.
Environment fit. Temperature, moisture, dust, vibration, light exposure, mounting position, and airflow can matter as much as the sensor element.
Interface fit. Check analog scaling, digital bus addresses, interrupt pins, timing requirements, cable length, and required pull-ups or termination.
Power fit. Measure active current, idle state, warm-up behavior, and whether the sensor can be duty-cycled without corrupting readings.
Calibration fit. Record the reference method, expected offset, recalibration need, and how raw readings will be converted into meaningful engineering units.
11.3.1 Reading a Sensor Spec Sheet
The five evidence lanes need a source. Start with the manufacturer’s spec sheet for the exact part. A piezoresistive sensor uses a material whose resistance changes when strain is applied. The sensing method helps you decide how the part must be mounted and tested.
- Header block. Use the manufacturer’s ordering and marking information to match the full orderable part number, package, and markings to the part on the bench. Record the document revision and publication date to identify the spec sheet edition. A revision change can move a spec row without changing the marketing name. When the silicon revision matters, verify it using the manufacturer’s revision identifier or errata that explain which identifier corresponds to each silicon revision.
- Product description: a short paragraph naming the sensing principle (capacitive, piezoresistive, thermal, optical, and so on), the package, and the supply range. This is where mounting orientation, moisture sensitivity, and package footprint start.
- Specification table: the real evidence. Parameters are usually reported as Minimum, Typical, and Maximum rather than one number, because manufacturing spread is real, and the table states the exact supply voltage and temperature the numbers were measured at.
- Measurement conditions: the fine print above or beside the table tells you whether a spec still holds at your rail voltage and enclosure temperature, or whether it needs re-verification on the bench.
Consider the Kionix KXR94-1050, a ±2 g accelerometer. First check power: its operating supply range is 2.5 to 5.25 V. The example values below are typical at 2.8 V, so test again if the supply or other conditions differ.
Sensitivity of 560 mV/g means the output changes by about 560 mV for each 1 g change in acceleration under those test conditions. At 2.8 V and 25 °C, the typical zero-g offset is 1.4 V, with a listed range of 1.358 to 1.442 V. That baseline matters when converting voltage to acceleration; compare the exact part with a known reference and record its calibration. Use the min and max values from the exact datasheet revision, rather than the unverified sensitivity bounds in the illustration. Check the -40 to 85 °C operating range and noise density against the site and required resolution before accepting the part.
Treat the spec sheet the way this chapter treats a breakout module: as a source to extract evidence from and cite in the acceptance record, not a document to file away once the part is ordered. A component record that says “560 mV/g typical at 2.8 V, 2.5-5.25 V operating supply, -40 to 85 degrees C, per the current datasheet revision” is stronger evidence than a record that only names the part.

Simulation · interactive
Component Acceptance Evidence Review
Write a component acceptance note covering supply voltage, bench evidence, and unresolved risks.
11.3.2 Selection Workflow: Sensor Families
Use families as starting points, then verify the specific component.
A physical switch can briefly make several transitions from one press. Debounce filters or waits out those transitions so the system reports one intended action.
- Environmental sensing covers temperature, humidity, pressure, light, gas, particle, and fluid conditions. These sensors often need placement and calibration review.
- Motion and position sensing covers acceleration, orientation, vibration, rotation, distance, and presence. These sensors often need mounting and noise review.
- Electrical sensing covers voltage, current, resistance, state, pulse counting, and power monitoring. These sensors often need isolation and measurement-range review.
- Human input sensing covers buttons, switches, touch pads, encoders, and proximity controls. These sensors often need debounce, accessibility, and enclosure review.
For the greenhouse logger, use these families to find candidates, then return to the five evidence lanes. The useful record explains the decision a reading will support, the test conditions, and the raw evidence needed before acceptance.

Knowledge check · self-test
Check: Sensor selection
Review sensor range, site conditions, calibration, and the evidence to save before acceptance.
Summary
A component choice connects a requirement to a candidate, boundary conditions, bench evidence, and a recorded decision. For the greenhouse logger, that means checking the sensor bus and ADC range, the microSD write burst, radio setup and recovery, and the pump’s startup load before accepting the assembled path.
Test parts alone, then add the real cable, enclosure position, bus neighbors, and loads one at a time. Save versions, wiring, raw readings, supply traces, and failure behavior so someone else can repeat the choice. When a module becomes a PCB, preserve the support circuit as well as the named chip. For sensors, accept only a fit across measurement, environment, interface, power, and calibration evidence.
Choose a sensor cable route. Keep the soil probe, lead length, soil condition, and supply the same. Compare repeated readings with the pump off and running for each route.
| Cable route | Pump off | Pump running |
|---|---|---|
| Beside the pump wiring | Readings hold steady | Readings vary |
| Away from the pump wiring | Readings hold steady | Readings hold steady |
These practice readings are hypothetical. Which route would you try first, and why? Log your choice and the remaining field check. For these readings, try the route away from the pump wiring first because its readings stayed steady with the pump running. Repeat the pump-off and pump-running comparison at the greenhouse with the installed cable before accepting the route.
A part earns its place through repeatable evidence under the intended conditions. A familiar part number or a successful demo is only the start of that decision.