← Back to the chapter · Previous detail

Technical detail · Industrial and Wearable Kits

Antenna power and current-loop headroom

dBm states power relative to one milliwatt; dBi describes antenna gain relative to an imaginary antenna that radiates equally in every direction. EIRP combines transmit power and antenna gain as an equivalent radiated power. In a current loop, the burden is the receiver resistance that develops a voltage from the current. Headroom is the supply voltage left after the cable and burden drops, available for the transmitter and other needs.

American Wire Gauge (AWG) is a wire-size designation. Wire size determines resistance per unit length, and the current travels out and back, so both conductors contribute to the loop resistance. The example uses 500 m each way for the stated cable resistance.

The mathematical gist. A fixed 14 dBm gateway with a 6 dBi patch has 20 dBm EIRP; a 0 dBm wearable with a 0 dBi antenna has 0 dBm EIRP, a 20 dB system difference that gives a 10.0× ideal range ratio. On a 500 m, 24 AWG cable, a 20 mA loop sees 84.2 Ω and needs 6.68 V across cable plus a 250 Ω burden, leaving part of the 24 V supply for the transmitter and other needs. Check the selected transmitter’s minimum operating voltage before accepting that margin.

At 1,000 m, the round-trip cable resistance is 168.4 Ω. At 20 mA, cable plus the 250 Ω burden drops about 8.37 V: 0.020 × (168.4 + 250). The supply must also cover the selected transmitter’s minimum compliance voltage. While that headroom remains, the far-end current is unchanged. A plain voltage signal would lose 3.37 V across that cable resistance. At 750 m and 126.3 Ω round-trip resistance, the same calculation gives 7.53 V across cable plus burden.

← Back to the chapter · Previous detail