← Back to the chapter · Next detail →
Technical detail · PCB Design and Fabrication
Copper trace resistance and skin depth
A longer or narrower copper trace has more resistance, so current through it causes a larger voltage drop. Thickness matters too. At high frequency, current tends to concentrate near the copper surface. Skin depth describes how far that current penetrates: compare it with the trace thickness to judge whether current is spread through the copper or mostly near its surface.
The mathematical gist. For a 50 mm long, 0.50 mm wide, 35 µm copper trace, . It drops 5.76 mV at 120 mA and 24.0 mV at 500 mA. Skin depth is 92.3 µm at 500 kHz but only 2.16 µm at 915 MHz, so a DC trace rule cannot stand in for an RF layout rule.