Size bulk capacitance from the measured transient
Size the local bulk capacitor from the charge the transient demands: Q = I x dt, and C = Q / dV for an allowed voltage droop dV.
Worked example. Suppose the radio pulls an extra 300 mA and the regulator takes ~10 us to respond, and you can tolerate a 0.1 V droop. Then Q = 0.3 A x 10 us = 3 uC, and C = 3 uC / 0.1 V = 30 uF. A 47-100 uF bulk capacitor placed close to the pin is therefore a candidate for this surge, paired with a small 0.1 uF ceramic for the high-frequency edge. Verify the allowed droop on the revised board. A capacitor can supply the 150 mA deficit of a 400 mA pulse from a 250 mA regulator for a limited time. Size it for pulse duration and allowed droop, including real component losses. Check recharge time between pulses and the regulator’s peak, thermal, and stability limits. A sustained overload cannot be solved by capacitance alone.