← Back to the chapter · Previous detail · Next detail →

Technical detail · Energy Sources for IoT Devices

Make capacity derating explicit

Raw capacity is Qraw = Iavg × Tdeployment, using measured average current and required service duration. Rated capacity is Qrated = Qraw / usable_fraction; state which derating and reserve are included.

If a node needs 1577 mAh raw charge for one year, a 70% usable-capacity assumption raises the source requirement to 1577 / 0.70 = 2253 mAh. Reserving 20% of the resulting total for service changes the target to about 2253 / 0.80 = 2816 mAh. Reviewers should see which step comes from chemistry, environment, reserve policy, or measurement uncertainty, rather than a single unexplained safety factor.