← Back to the chapter · Next detail →
Technical detail · Energy Sources for IoT Devices
What is inside the usable-capacity fraction?
At 1% annual self-discharge, 98.01% of stored charge remains after two years. The loss is 1.99% (about 2.00 percentage points), so shelf loss explains only about 2 of the chapter’s 35 derating percentage points.
Separately, a 15 mA pulse through a fresh 25-ohm cell leaves 2.625 V from a 3.0 V open circuit. An end-of-life 200-ohm linear model gives 0 V at that same current. It signals that the real cell cannot sustain the requested pulse; the model is not evidence that the cell will deliver that current at a useful terminal voltage.