Technical detail · Energy Sources for IoT Devices

Convert a source gap into buffer energy

Use Eload = Pload × t when converter losses, mixed voltages, or harvesting paths matter. Check Eharvest usable >= Eload + reserve across poor-source intervals, not just typical days.

If the load needs 20 mW for a six-hour source gap, the buffer must deliver 20 mW × 6 h = 120 mWh. With 75% storage and converter efficiency, it must store about 120 / 0.75 = 160 mWh, plus reserve. At 3.7 V nominal storage voltage, that is roughly 160 mWh / 3.7 V = 43 mAh before ageing and low-temperature effects. Repeat the check for startup, radio retries, and recovery after depletion.