The meter changes what it measures

Burden voltage can perturb current measurement. If the shunt drops a significant voltage during a current spike, the device's supply sags at exactly that moment. A sagging supply can change how much current the device draws - a regulator works harder, a radio adjusts its output, or the chip approaches brownout - so the measurement changes the device behavior. Keeping burden small, or using an instrument that regulates the voltage at the device despite the shunt, is what makes the measurement represent reality.

The second is bandwidth. Radio and processor currents change in microseconds, but an averaging multimeter reports a slow mean. A meter that shows 0.4 mA average tells you nothing about a 200 mA pulse hiding inside that average, and it is precisely that pulse that might brown out a coin cell. Capturing peaks needs a fast sample rate and enough amplifier bandwidth to follow the edges; an undersampled trace both misses the peak height and mis-estimates the charge in short bursts. This is why an average-only reading and a high-bandwidth capture answer different questions, and a full energy profile needs both.

A quick perturbation check makes the problem visible. If a temporary 1 ohm shunt sees a 200 mA radio pulse, the meter removes 0.200 A x 1 ohm = 200 mV from the device rail during exactly the highest-load event. On a partly discharged 3.0 V system that may be the difference between a clean packet and a brownout-driven retry. If the trace changes when you replace the 1 ohm shunt with 0.1 ohm, the first trace included an instrument-induced behavior.

Bandwidth creates the opposite failure: the circuit is not disturbed, but the evidence is blurred. A 120 mA transmit edge lasting 2 ms carries 120 mA x 0.002 s = 0.24 mA-s. Averaged over a 60 s reporting interval, that event is only 4 uA, so a slow logger can make the peak look harmless even though the source must deliver the full pulse instantly. Use fast traces for peak feasibility and integrated charge for lifetime estimates.

An auto-ranging instrument also has a brief settling window during a range change. Know where these range-switch glitches leave blind spots in the trace.