22.11 Usable Capacity Depends On Your Brownout Threshold

For a pulsed load, "usable capacity" is not a fixed fraction of the label. It is set by the point where the sagging pulse voltage first touches your brownout threshold. Because internal resistance rises as the cell depletes, the sag grows over life: a pulse that dropped 0.1 V when fresh may drop 0.5 V or more near the end. The higher your pulse current and the higher your brownout voltage, the earlier that crossing happens - and the more of the rated 220 mAh you leave stranded in the cell.

This is why a design must pass two independent checks. The average-current check tells you whether there is enough energy for the target lifetime. The peak-pulse check tells you whether the cell can deliver each burst without browning out. A design can pass the first and fail the second: comfortable average current, plenty of mAh, and still an early death because the aged cell can no longer swallow the transmit pulse. A reservoir capacitor, a lower-resistance cell chemistry, or a gentler radio setting moves the crossing later and unlocks more of the stored charge.

A quick threshold calculation shows the effect. If the open-circuit cell is at 2.6 V and the radio pulse is 10 mA, a 2.4 V brownout allows only (2.6 - 2.4) / 0.010 = 20 ohm before reset. A 2.0 V brownout allows (2.6 - 2.0) / 0.010 = 60 ohm. The same cell and the same average current can therefore deliver very different field life depending on the minimum voltage of the regulator, microcontroller, sensor, and radio chain. Treat the brownout threshold as a design variable to review, not as a hidden firmware detail.

← Back to the chapter · Previous detail