Exclude and restore one range sensor
Isolation should also record which state dimension was protected. If range sensors A, B, and C report residuals of 0.08 m, 0.11 m, and 0.72 m while the configured gate is 0.30 m, the system can exclude C from the position update without marking every sensor unhealthy. The published state should then say "two-of-three range evidence, C excluded, position-only confidence widened" rather than simply "healthy". If the excluded sensor later returns with residuals of 0.09 m, 0.07 m, and 0.06 m over three windows, the recovery rule can allow it back in. If it returns once at 0.09 m and then jumps to 0.41 m, it stays quarantined and the maintenance record remains open. This prevents a single lucky sample from hiding a loose mount, bad reference, or intermittent cable.