← Back to the chapter · Next detail →
Technical detail · Sensor Fusion Best Practices
Calculate a scalar innovation gate
Worked example: scalar innovation gate predicted temperature: 22.0 deg C predicted variance P: 0.25 new measurement z: 25.0 deg C measurement variance R: 0.25 innovation: y = z - prediction = 25.0 - 22.0 = 3.0 innovation variance: S = P + R = 0.25 + 0.25 = 0.50 normalized innovation squared: NIS = y^2 / S = 9.0 / 0.50 = 18.0 decision: For a one-dimensional 95 percent chi-square gate, the threshold is about 3.84. 18.0 is above that gate, so reject or quarantine this measurement. Do not feed it into the fused state until the cause is understood.