Technical detail · Sensor Fusion Architectures

Shared evidence and track covariance

Worked example: track-to-track covariance check
tracker A position: x = 10.2 m, sigma = 0.4 m
tracker B position: x = 10.4 m, sigma = 0.4 m

If the estimates are independent:
precision for each tracker = 1 / 0.4^2 = 6.25
combined position = (10.2*6.25 + 10.4*6.25) / 12.5 = 10.3 m
combined sigma = sqrt(1 / 12.5) = 0.28 m

If both trackers used the same upstream UWB anchor observation, that 0.28 m
confidence is optimistic because the same evidence was counted twice. The
architecture should mark common sources, correlation assumptions, and any
covariance inflation rule before publishing the fused state.

This is why architecture diagrams should show common sources and summary boundaries, not only arrows. A state-level fusion service needs to know whether two tracks came from independent sensors, from two gateways that shared one anchor, or from two classifiers trained on the same labeled incident set. When independence is unknown, a conservative design keeps the larger uncertainty, flags the common-source path, or routes the fused output for review before it drives actuation.

Use Kalman Filters to follow state and covariance through estimates over time. Complementary IMU Fusion places fast and slow sensor corrections in a practical embedded design.