ADC Sampling and Quantization

ADC Sampling and Quantization

animation
signal-processing

A pressure sensor that outputs 0.5 to 2.5 V into a 12-bit, 3.3 V ADC has about 0.806 mV per code across the ADC reference, but the useful question is not the ADC number alone. If the signal-conditioning circuit leaves 2 mV RMS noise on the input, several adjacent codes can represent the same pressure state. Averaging may make the displayed pressure steadier, but a long window can also hide a short pressure pulse from a pump or valve. The right design compares three quantities together: the smallest pressure change that matters, the voltage represented by one code, and the measured noise plus required response time.