Sensor Noise Lab Activities
Sensor Noise Lab Activities
Sensor Noise Lab Activities
Change the Noise Before Adding More Samples
Record raw values at a fixed input. Move the motor, change sample rate, shorten the wires, add shielding, average several window sizes, and repeat after warm-up. Compare spread, bias, response time, and missed events.
Still-Air Baseline
A practical lab sequence is to collect a still-air baseline first. Hold the sensor at a stable reference, sample at the intended rate, and compute mean, standard deviation, minimum, maximum, and obvious outliers. Then repeat after changing exactly one variable: add a fan, move the cable near a motor lead, change the supply, or alter the averaging window. If the standard deviation falls as roughly 1/sqrt(N), the noise is mostly white and averaging is doing real work. If the mean walks while the standard deviation looks small, you are seeing drift or placement error, and the fix is calibration or environment control.
Pause and Compare
A useful field diagnostic is the “pause and compare” test. Log raw values, filtered values, and the decision output at the same time. If the raw value jumps but the filtered value recovers, the filter is absorbing random noise. If raw and filtered values both creep in the same direction, suspect drift, heating, supply movement, or the reference condition itself. If two redundant sensors disagree by a fixed amount, treat that as calibration mismatch; if they disagree only during motor activity, treat it as coupling or grounding. That evidence-first habit is what makes sensor best practices auditable.
Front-end Noise Bandwidth
The next workbench makes the front-end crossover visible instead of leaving it as separate equations. Begin with the wide noisy preset, where the integrated analog floor dominates. Change only the upper band edge from 1010 Hz to 110 Hz: the shaded band contracts, SNR improves, and quantization becomes the larger remaining floor—but the converter itself remains exactly 16 bit.
Change only Upper band edge, narrowing it from 1010 Hz down to 110 Hz, then explain why SNR and effective bits improve while nominal ADC resolution stays 16 bit.
Technical boundaries. The baseline comparison assumes a stable reference, the intended sampling rate, and exactly one changed variable at a time. The bandwidth exercise keeps the converter at 16 bit while changing only the upper band edge, which narrows from 1010 Hz down to 110 Hz.