Try the Battery-Life Tradeoff

Try the Battery-Life Tradeoff

animation
sensors
braitenberg
Try Keep Active current draw (mA) at 280 and reduce Active minutes per day from 5 to compare daily draw.
Observe With 2500 mAh capacity and 10 uA sleep current, the opening estimate is 106 days, about 3.5 months.
Explain Active minutes per day is converted to hours; active charge and charge used during the rest of the 24-hour day are added before dividing battery capacity by daily draw.

Technical boundaries. The estimate assumes fixed current in each state and full usable battery capacity, with no self-discharge or ageing. Quantities labelled energy in mAh are charge; voltage is not an input, and a month is fixed at 30.44 days.

Try the Battery-Life Tradeoff

Energy use depends on both current and time in each state. Compare the cycle totals before choosing a design. The calculator’s mAh readouts are charge, not energy. Energy also depends on voltage.

Key insight: this reactive system is simpler than using a camera, vision pipeline, servo controller, and compass for the same task.

Back to the chapter