Separate Nominal Bits from Useful Resolution

Separate Nominal Bits from Useful Resolution

animation
adc
sampling

Interactive: Separate Nominal Bits from Useful Resolution

The sample plan is incomplete until voltage resolution, input noise, sensor sensitivity, and observation time are read from the same ledger. Open the sensor-specification preset below, keep the 3.30 V range and 12-bit converter fixed, and change only the averaging count from 1 to 64. The visible gain in effective bits is purchased with a longer acquisition window; nominal ADC width has not changed.

Carry both results into the sample-plan record. A design that reports the smaller uncertainty but omits the longer observation time has described only half of the trade-off.

Return to ADC fundamentals