TryLeave TX event duration (µs) at 500 and increase Connection interval (ms). Compare the current and battery-life rows before and after the change.
ObserveWith the opening TX event duration (µs) of 500, the table shows Duty cycle, Average current and Estimated battery life. The default Best for line reads Fitness tracker / health monitor.
ExplainTX event duration (µs) divided by Connection interval (ms), after converting both to seconds, gives the active time share. The tool weights TX and sleep currents by their time shares, then divides battery capacity by average current.
Technical boundaries. The estimate assumes one transmit event per interval and sleep for the remaining time. Battery capacity is used in full at a constant average current, without accounting for self-discharge, aging or other device activity.
NoteTry It: BLE Connection Interval Power Estimator
See how connection interval affects battery life. Shorter intervals mean faster response but higher power consumption — find the right balance for your application.