ADC resolution and sensor specification

ADC resolution and sensor specification

animation
sensors
Try In the embedded workbench, change Average count from 1 to 64 while leaving the noisy LM35 preset selected.
Observe The starting readouts show 9.19 useful bits and 0.564 degrees C effective resolution. Averaging 64 samples improves them to 11.6 bits and 0.107 degrees C while acquisition takes 64.0 ms.
Explain Average count reduces the independent noise term by its square root, while acquisition time equals the sample count divided by the sample rate.

Technical boundaries. The model assumes independent RMS noise combined with quantization noise by root-sum-square. It uses an ideal unipolar converter and excludes offset, reference drift and correlated noise.

The workbench below turns that trade-off into a sensor specification decision. It opens on a 3.30 V, 12-bit converter with 2.00 count RMS independent noise, one sample per result, 1000 sample/s, and the LM35 sensitivity of 0.0100 V/deg C. Walk through the orange uncertainty band and live readouts first: the starting result is only 9.19 useful bits and 0.564 deg C effective resolution. Then change only Average count from 1 to 64. The useful result reverses to 11.6 bits and 0.107 deg C, but the acquisition window grows from 1.00 ms to 64.0 ms. That visible exchange is why a module specification must record both resolution and observation time instead of quoting nominal ADC bits alone.