Relay Derating Calculator for Inductive Loads

Relay Derating Calculator for Inductive Loads

animation
actuators
relays
Try Leave Load Current (A) at 8 and change Load Type from Resistive (heater, incandescent) to Inductive (motor, L/R > 5ms).
Observe The default resistive load shows an 8.0 A minimum rating and a 9.6 A recommendation. Watch both ratings rise when you select the inductive load.
Explain Load Current (A) is divided by the selected derating factor, then multiplied by 1.2 for the recommendation.

Technical boundaries. This calculation assumes fixed factors of 1.0, 0.4 and 0.1 for resistive, inductive and lamp loads. The example relay list stops at 30 A even when the calculated recommendation exceeds that rating.

Interactive: Relay Derating Calculator for Inductive Loads

Back to the chapter