← Back to the chapter · Next detail →

Technical detail · Z-Wave Architecture and Devices

A sleepy endpoint's battery and regional antenna budget

A catalog-typical 850 mAh cell leaves about 647 mAh after five years of 1% self-discharge and a 20% reserve, which permits 14.8 µA average. The wake, event, and sleep example averages 2.37 µA. Regional carriers also set different quarter-wave targets: 8.64 cm at 868.42 MHz, 8.26 cm at 908.42 MHz, and 8.14 cm at 921.42 MHz. These figures connect a sleeping endpoint’s availability to its power budget and the correct radio region.