Technical detail · RFID Read Troubleshooting
Power and dwell time in the installed zone
Reader power also needs units. Raising conducted power from 27 dBm to 30 dBm is a 3 dB increase, roughly double the conducted power before antenna and regulatory limits. Doubling power can help marginal wake-up cases, but it also expands the field into nearby shelves and staging areas. If the baseline has 45 / 50 intended reads and 1 / 50 wrong-zone reads, and the higher-power test has 49 / 50 intended reads but 11 / 50 wrong-zone reads, the change is not acceptable without antenna, shielding, or middleware changes.
Dwell time closes the loop. A pallet crossing a 2.0 m useful read zone at 1.0 m/s stays in the zone for 2.0 / 1.0 = 2.0 seconds. If the reader cycles four antennas evenly, each antenna has roughly 2.0 / 4 = 0.5 seconds before the geometry changes. A dense-tag miss may be an inventory timing problem, not a tag defect. Good troubleshooting asks whether the selected power, antenna sequence, inventory behavior, duplicate window, and event rules all fit inside the actual motion of the workflow.