Technical detail · RFID Standards and Protocols
Why gain means something different at 13.56 MHz
At 13.56 MHz, wavelength is 22.1 m and the near-field screen is 3.52 m, so 2–10 cm HF reads are magnetic-coupling problems. At 915 MHz, a 0.3 m portal reaches its far-field screen by 0.549 m; a 36 dBm EIRP, 2 dBi tag, and −18 dBm wake threshold give a 16.5 m ideal forward-link ceiling, not a guaranteed read zone.