Why field boundaries are not read ranges

The approximate near-field boundary is r≈λ/(2π)r\approx\lambda/(2\pi), where λ=c/f\lambda=c/f. This separates field behavior; it does not predict a tag’s read range. At 125 kHz, wavelength is 2,400 m and the boundary is 382 m, about 1,273 times a 0.3 m LF read. At 13.56 MHz, wavelength is about 3.0×108/(13.56×106)=22.1 m3.0\times10^8/(13.56\times10^6)=22.1\ \mathrm{m}, giving r≈3.52 mr\approx3.52\ \mathrm{m}, about 35 times a 0.1 m HF tap. Coil size, tuning, protocol, power, orientation and losses usually constrain a practical tap much more tightly.

At 915 MHz, wavelength is about 0.328 m and λ/(2π)≈0.052 m\lambda/(2\pi)\approx0.052\ \mathrm{m}. Warehouse UHF systems therefore operate mainly in a propagating regime beyond a few centimetres. Polarization, multipath, water absorption and detuning near metal matter there.

Antenna gain also trades coverage angle against directionality. Changing a UHF portal from 6 to 9 dBi halves its ideal solid-angle fraction. At the same equivalent isotropically radiated power (EIRP) cap, that gain change does not increase the ideal forward-link range. Review coverage and the available dwell window together rather than assuming more gain solves every missed read.