← Back to the chapter · Previous detail
Technical detail · Choosing a Prototyping Kit
RTD and antenna migration evidence
A PT100 RTD has a resistance of 100 Ω at 0 °C. A ratiometric converter compares that resistance with a known reference, so the ratio determines the code. EIRP expresses power in a particular direction as transmitter power adjusted for feed loss and antenna gain.
The mathematical gist. For a PT100, with and gives, in the linear approximation used here, a resistance at −20 °C of 92.3 Ω. A 15-bit ratiometric front end with a 430 Ω reference reports about 7,034 counts and a 0.0341 °C step. In the same migration review, a 4 dB antenna-gain loss reduces EIRP in that direction by a factor of , assuming unchanged input power and feed loss.
The code calculation is . The 0.0341 °C value describes a code step in this model; it does not establish measurement accuracy.