RTD and antenna migration evidence

A PT100 RTD has a resistance of 100 Ω at 0 °C. A ratiometric converter compares that resistance with a known reference, so the ratio determines the code. EIRP expresses power in a particular direction as transmitter power adjusted for feed loss and antenna gain.

The mathematical gist. For a PT100, R=R0(1+αT)R=R_0(1+\alpha T) with R0=100 ΩR_0=100\,\Omega and α=0.00385 ∘C−1\alpha=0.00385\,{}^\circ\mathrm{C}^{-1} gives, in the linear approximation used here, a resistance at −20 °C of 92.3 Ω. A 15-bit ratiometric front end with a 430 Ω reference reports about 7,034 counts and a 0.0341 °C step. In the same migration review, a 4 dB antenna-gain loss reduces EIRP in that direction by a factor of 104/10=2.5110^{4/10}=2.51, assuming unchanged input power and feed loss.

The code calculation is 92.3/430×32,768≈7,03492.3/430\times32{,}768\approx7{,}034. The 0.0341 °C value describes a code step in this model; it does not establish measurement accuracy.