← Back to the chapter · Previous detail

Technical detail · Low-Power Design: Leakage and Body Bias

Follow the chopper amplifier signal path

9.4.1 Chopper Amplifier Signal Path

Chopper stabilization separates a low-frequency input from the amplifier’s own low-frequency error by multiplying twice with a square wave m(t)∈{−1,+1}m(t)\in\{-1,+1\}.

  1. The first mixer forms xm(t)=x(t)m(t)x_m(t)=x(t)m(t). A baseband sensor signal moves to odd harmonics of chopping frequency fchopf_{chop}.
  2. The amplifier processes that modulated signal. Its offset and internal 1/f1/f noise are added after the first mixer and therefore remain near baseband at this point.
  3. The second synchronous mixer multiplies by the same phase. Because m2(t)=1m^2(t)=1, the wanted signal returns to baseband: x(t)m(t)m(t)=x(t)x(t)m(t)m(t)=x(t).
  4. The amplifier offset and low-frequency noise are multiplied only once, so they move to fchopf_{chop} and its odd harmonics.
  5. A low-pass filter passes the recovered sensor band and rejects the translated error and switching artifacts.

An ideal 50% square wave has odd-harmonic coefficients proportional to 1/(2k+1)1/(2k+1), so the first modulation produces replicas around fchop,3fchop,5fchop,…f_{chop},3f_{chop},5f_{chop},\ldots. Choose fchopf_{chop} comfortably above the signal band and the amplifier’s flicker corner, while leaving enough amplifier bandwidth and filter separation for settling.

In Figure 4, the three spectra share a frequency axis that lets you compare signal and error before, between, and after the mixers.

A signal path with a square-wave-driven mixer, amplifier with offset and flicker noise injected, a second synchronous mixer, and a low-pass filter. Three stacked spectra share one frequency axis: at the input the signal sits near DC; inside the amplifier the signal has moved to the first, third and fifth chopping harmonics while offset and flicker noise enter at DC; after the second chop the signal is back at DC inside the filter passband while the amplifier error is parked at the odd harmonics with small chopping artifacts at even ones.
The first chopper moves the sensor signal away from baseband before amplification. The second returns that signal to baseband while translating amplifier offset and flicker noise outside the low-pass band.

Follow Figure 4 from input through the first mixer, amplifier A, second mixer and LPF to output. The same square wave drives both mixers. Offset and internal 1/f noise enter at the amplifier, after the first mixer. The three spectra below share one frequency axis. Panel A places the blue wanted signal near DC. Panel B moves it to odd chopping harmonics while the red amplifier error stays near baseband. Panel C brings the signal back inside the filter band and moves the error to odd harmonics. Small gray marks show switching artifacts at even harmonics.

Input noise that exists before the first mixer follows the wanted signal back to baseband. Switch charge injection, clock feedthrough, finite gain-bandwidth, and phase mismatch create ripple and residual offset. Measure input-referred noise, ripple spectrum, overload recovery, and settling over the complete sampling window.

← Back to the chapter · Previous detail