← Back to the chapter · Next detail →
Technical detail · Power Management Tools
Add self-discharge to the hourly baseline
The hourly device draws about 26.9 microamps. A 1000 mAh cell gives a naive 4.24-year estimate. Approximating self-discharge of 2% per month as a constant loss based on nominal capacity adds an equivalent 27.8 microamps. The total becomes 54.7 microamps, giving about 2.09 years under that approximation.
Lifetime sensitivity follows . The value of removing one more microamp falls from about 1,382 hours to 334 hours when that extra loss is included. This is a simplified comparison, not a guaranteed field lifetime: the self-discharge allowance must match the cell and deployment.