Series-parallel harvesting converter
A converter becomes reviewable when feedback and release gates are visible. Figure 4 opens the path from weak ambient sources to a regulated, power-good load rail.
In Figure 4, Rectify and accumulate includes the cold-start condition before a regulated controller supply exists. Switch-capacitor stages use non-overlap φ1 / φ2 clocks, Sense and choose gain prevents source collapse, and Qualify the load rail uses hysteretic power-good rather than exposing the load to a chattering undervoltage rail.
A switched-capacitor converter changes voltage by reconfiguring flying capacitors between charge and transfer phases. In one phase capacitors charge in a series or parallel arrangement; in the other, switches reconnect them so their voltages add, divide, or transfer charge to the output. A family of switch configurations provides discrete conversion ratios. An eight-ratio design can therefore cover a 0.6–2.4 V source while regulating a roughly 1.2 V load more efficiently than one fixed ratio across the whole range.
Follow the control loop:
- A source such as light, vibration, a temperature difference, or rectified RF charges an input reservoir. Its series resistance is part of the source model.
- A reference and feedback divider compare with the target rail.
- A gain controller selects one of the available capacitor ratios so the ideal converted voltage sits near the target rather than forcing regulation through avoidable loss.
- A non-overlap clock generator creates phases and that are never high together. This prevents switches from momentarily shorting a charged capacitor or supply node.
- The switch matrix moves charge through the selected series-parallel topology.
- A current sensor and oscillator adjust switching frequency: more frequent packets of charge support load, while a weak source or light load needs a lower rate to avoid switching loss.
- Power-good logic releases the load only after the storage/output node is usable and can return it to reset before an uncontrolled brownout.
The converter does not create energy. For ideal ratio , , while real output is bounded by efficiency:
Ratio changes, bottom-plate parasitics, switch resistance, clock generation, leakage, and charge redistribution all reduce . This is why ratio selection and frequency control must be measured over source voltage and load current, not validated at one nominal point.