Technical detail · Energy Harvesting: Source Reality and Field Proof
Finite-store clipping and capacity limits
The finite-store ledger makes that clipping mechanism inspectable slot by slot. Begin with the 10 mJ store, then change only Harvest scale from 1.00 to 1.50: the arrival total grows, but the extra burst spills before later service can use it.

Simulation · interactive
Energy Harvesting Calculator
Step through arrival-before-service and change only Harvest scale from 1.00 to 1.50 to explain the useful-work and served-power plateau.
Finite storage changes the problem. A single arrival is admitted as
so the usable mean can fall below the harvested mean. A rough empty-buffer clipping approximation replaces arrivals by , but
is not a general finite-battery capacity formula. Actual overflow depends on the current buffer and power-control policy, and the logarithm is concave, so bursty power allocation does not behave like constant average power. Capacity is obtained by optimizing an energy-causal policy over the buffer state and arrival statistics, commonly through dynamic programming or Markov decision methods after discretization.
This produces three engineering regimes:
- If comfortably spans the largest relevant energy drought and burst, the infinite-buffer approximation can be useful.
- If arrivals frequently overflow the store, increasing capacity or transmitting opportunistically can recover otherwise discarded energy.
- If the store is often empty, the policy must reserve energy for deadlines or channel opportunities; the mean arrival alone is misleading.
The design sequence is therefore: characterize the arrival distribution and correlation; measure conversion and leakage losses; choose a candidate ; simulate the state recursion with real traces; optimize or compare causal policies; then report throughput, outage, overflow, and missed-deadline rates together.