Temperature can erase the lifetime margin

Self-discharge is a chemical reaction. A rough rule of thumb is that its rate can nearly double for every 10 °C increase; this is a sensitivity assumption to check against the chosen cell, not a universal chemistry law. A sunny rooftop enclosure can therefore consume the margin calculated from a room-temperature rating. Battery University discusses elevated self-discharge.

Using that assumption, a 3 µA Li-SOCl2 allowance at 20 °C becomes 3 µA × 2 × 2 = 12 µA near 40 °C. The 15 µA sensor now budgets 27 µA before radio-pulse margin. With 2340 mAh usable, 2340 / 0.027 ≈ 86667 h, or about 9.9 years. A room-temperature estimate comfortably above 10 years becomes marginal in the enclosure.

Cold creates other limits. Alkaline can deliver only a fraction of its rated capacity below freezing. Li-ion can discharge in the cold, but standard cells must not be charged below 0 °C: lithium plating can permanently damage them. Cold solar nodes need a charge-temperature gate or another chemistry, following the exact cell specification.

Li-SOCl2 tolerates very wide temperatures but can suffer passivation after long storage or cold soaking. This surface film delays voltage recovery under a sudden pulse, weakening the first pulse until the film clears. A low annual self-discharge figure does not establish pulse performance. Budget temperature, usable capacity, charge limits, and voltage delay together.