What a MEMS sensitivity row is made of

A proof mass is a tiny movable weight inside the sensor. Springs hold it in place; acceleration moves it relative to the case. Fixed electrodes form a capacitor across a small gap, and movement changes that gap and the capacitance. Readout electronics detect the change and convert it into a voltage or digital measurement. The mathematical gist. With a 30 µg proof mass, 8 N/m spring, and 2 µm gap, a 2 g input deflects the mass 73.6 nm, or 3.68% of the gap. That changes a 2 pF capacitance by 0.0736 pF and produces 73.6 mV through the stated 1 pF, 1 V readout—an internal 36.8 mV/g teaching estimate whose constants all carry tolerance.