← Back to the chapter · Previous detail
Technical detail · NB-IoT Coverage Enhancement
Installed antenna loss and the teaching model
At 900 MHz, a 0 dBi antenna installed at 70% efficiency has −1.55 dBi realized gain and 21.45 dBm EIRP from a 23 dBm transmitter. At 15% efficiency, realized gain falls to −8.24 dBi and EIRP to 14.76 dBm. The 6.69 dB installation penalty is an ideal 4.67× repeated-energy equivalent, not a coverage guarantee.
NB-IoT Coverage Narrated Tour
The narrated workbench uses a basement water meter sending 32 bytes daily with 128 transmissions and a required loss tolerance of 162 dB. Path loss describes signal lost along the radio path. Its ideal repetition gain is 10 log₁₀(128): log₁₀(128) ≈ 2.107, giving 21.072… dB, or about 21.1 dB.
The teaching model caps that gain at 20 dB. Adding its 144 dB baseline gives 164 dB; capping available tolerance at 164 dB and subtracting the required 162 dB leaves +2 dB margin. These are model settings, not installation approval thresholds.
Its delay estimate is 32 × 3.2 = 102.4 ms, plus 90 ms = 192.4 ms, multiplied by 128 transmissions and the daily-reporting factor of 1: 24627.2 ms. Rounded to 24627 ms, this displays as about 25 s. The radio-time proxy is 128× baseline. Neither the modeled margin nor this proxy replaces measured delivery, time, and energy at the installed meter.