Battery charge and attach pulses

The mathematical gist. Five years of 0.7%/year self-discharge leaves 96.5% of a 3000 mAh cell, but retained charge does not prove pulse delivery. A 300 mA attach through 1.50 Ω sags 0.45 V, leaving 3.15 V from a 3.6 V cell. Through 15.0 Ω it requests 4.50 V of sag, so attach fails even while the mAh ledger looks nearly full.