← Back to the chapter · Previous detail · Next detail →
Technical detail · Audio Feature Extraction for IoT
Read the pre-emphasis, overlap, and taper plots
Three formulas have now been introduced, and each of them does something to the signal that a plot makes obvious in a second. Inspect the three panels of Figure 5 in order; the numbers marked on each plot are the ones from this chapter’s own 16 kHz pipeline.
Panel one of Figure 5 is the whole argument for : the response climbs from a gain of 0.03 at DC to 1.97 at Nyquist, so slow components are suppressed relative to rapid change — which is why the same curve can amplify high-frequency sensor noise on a machine that is not a talker. Panel two makes the overlap concrete: the 25 ms frame bar and its two successors are offset by the 10 ms hop, leaving 240 shared samples, so an event landing near one frame edge is analysed again inside the next. Panel three sets the Hamming taper against the rectangular window drawn as a dashed outline; the taper’s ends fall to 0.08 instead of stopping abruptly, which is what trades sidelobe leakage for a wider main lobe. Read together, the three panels are three measurement decisions, and none of them is recoverable from a model file that only says “MFCC”.