A 100 Hz vibration component requires a sampling rate above the 200-samples-per-second Nyquist boundary for unambiguous reconstruction. Downsampling it to 20 Hz supplies only that boundary rate, and Hz makes the vibration look like a DC offset. Filtering must happen before the rate change because later preprocessing cannot identify which slow-looking samples are aliases.
A separate 10-bit, 3.3 V analog-to-digital converter (ADC) limit gives a 3.22 mV step, 0.930 mV RMS rounding noise, and 62.0 dB ideal signal-to-noise ratio (SNR). Rate conversion does not remove that quantization limit.