The Beta model is referenced to a known resistance and temperature. At the reference resistance it returns the reference temperature.

Back to the chapter →

The Beta model is referenced to a known resistance and temperature. At the reference resistance it returns the reference temperature.

The result fits the curve's direction: an NTC element has lower resistance when warmer. Predict what resistance the same divider gives at half the supply voltage, 1.65 V. It gives 10 kΩ, so the ideal model returns the 25 °C reference point. That midpoint check catches several wiring and scale mistakes before a wider calibration trial.
Next, increase the sense current and observe a slow upward temperature bias in still air. Self-heating can warm the actual bead, so a more elaborate curve fit does not remove the physical cause. The module's linearization lesson joins circuit orientation, units, model parameters and calibration evidence. The ideal arithmetic needs validation with the exact part, reference and installed thermal conditions.

Back to Thermistor Linearization: Practitioner: The Beta Equation, Worked