Trace Shared Pickup and Thermal Drift in a Bridge
Trace Shared Pickup and Thermal Drift in a Bridge
Trace Shared Pickup and Thermal Drift in a Bridge
Bridge and amplifierBridge midpoints
Cable pair
Amplifier
Green: active-side wire · Purple: dummy-side wire
Bracket: wanted differential
Upper trace: active-side wire · Lower trace: dummy-side wire. Each dashed line is that wire’s own baseline. The traces are separated for readability.
Bracket: 100 mV from baseline to crest on the active-side wire. Both wires have the same 50 Hz pickup.
Subtract the dummy-side voltage from the active-side voltage at each instant. The shared pickup cancels and the 2 mV difference stays constant.
Ground-referenced single-ended stage
Gain 100 · Shared pickup appears on the measured wire.
10 V peak requested · Dashed upper guide: possible rail · Clipping depends on available swing.
Instrumentation amplifier
Both midpoint wires feed high-impedance inputs, drawing little current. Differential gain 100.
Shared pickup only · 50 Hz
100 dB CMRR → voltage rejection ratio 100,000.
100 mV ÷ 100,000 ≈ 1 µV peak input-equivalent.
After gain 100: about 0.1 mV peak output pickup.
Wanted signal
2 mV differential × gain 100 = 200 mV output.
The calculation assumes operation within amplifier limits.
Right bracket: baseline separation.
Left green bracket: excursion · Brown bracket: new separation · Right: baseline.
The change in separation is differential pickup.
Left upper arm: fixed R · Right upper arm: fixed R
Left lower arm: active gauge, baseline R · Right lower arm: unstrained dummy, baseline R
Active gauge: +0.05% thermal · Dummy gauge: +0.05% thermal
Active gauge: +0.20% strain contribution · Dummy remains unstrained.
Midpoints are measured against common return. The divider law still sets the resulting difference.
Active gauge at the warmer end · Unstrained dummy farther away · No applied strain
The difference arises at the bridge before amplification. The mismatch is qualitative.
The bridge carries strain as the voltage difference between its midpoints.
Technical boundaries. The cable traces are offset for readability, and the differential plot uses its own vertical scale. The instrumentation amplifier example assumes operation within amplifier limits, while actual single-ended swing depends on the available rails. The temperature gradient panel shows a qualitative mismatch.