Trace Shared Pickup and Thermal Drift in a Bridge

Trace Shared Pickup and Thermal Drift in a Bridge

Try Press Step once to compare the green active-side wire and the purple dummy-side wire when the motor pickup appears.

Trace Shared Pickup and Thermal Drift in a Bridge

Bridge and amplifier

Bridge midpoints

Cable pair

Amplifier

Midpoint voltages · magnified separation

Green: active-side wire · Purple: dummy-side wire

Bracket: wanted differential

The bridge carries strain as the voltage difference between its midpoints.

Observe Both wires show the same 50 Hz oscillation, with a 100 mV bracket from baseline to crest on the active-side wire. The separate differential plot stays flat at 2 mV.
Explain The wanted difference stays at 2 mV because subtracting the dummy-side voltage from the active-side voltage cancels the equal pickup at each instant.

Technical boundaries. The cable traces are offset for readability, and the differential plot uses its own vertical scale. The instrumentation amplifier example assumes operation within amplifier limits, while actual single-ended swing depends on the available rails. The temperature gradient panel shows a qualitative mismatch.

Back to the chapter