Trace Interference Through Decimation
Trace Interference Through Decimation
Trace Interference Through Decimation
DecimationAnalog low-pass
ADC
Digital low-pass
Decimate
Storage
Shaded: wanted band through 20 Hz · Brown: 38 Hz test tone borrowed from the chapter’s motor example.
Vertical position is schematic.
Blue: gradual analog low-pass roll-off near 40 Hz · Brown: fixed 38 Hz test tone.
Residual depends on measured attenuation.
Shaded: wanted band through 20 Hz · Brown: residual at 38 Hz · Right boundary: 100 Hz Nyquist.
This record feeds both digital branches.
Digital low-pass bypassed
Same 200 SPS ADC record and same starting tick in both branches. Retain every fourth tick.
Residual at 38 Hz in the ADC record.
Alias inside the wanted band: |38 − 50| = 12 Hz. Right boundary: 25 Hz Nyquist.
Digital low-pass before decimation
Preserve
Keep the wanted band through 20 Hz.
Attenuate
Suppress every ADC-record component that would fold into the wanted band to the level required by the error budget.
Measure upstream of digital filter
Estimate the 38 Hz component in the shared ADC record.
Digital low-pass
Apply measured or estimated rejection at 38 Hz.
Measure downstream of digital filter
Attribute the remaining 38 Hz component before decimation.
Same 200 SPS ADC record and same starting tick in both branches. Retain every fourth tick.
Alternative evidence
Compare a known injected tone with a tone-free reference.
Compare attributed residual with allowed error
A lone stored 12 Hz peak is source ambiguous. It can contain actual vibration, aliased interference, or both.
The wanted vibration band extends to 20 Hz. Follow the 38 Hz test tone through the acquisition chain.
Technical boundaries. The spectrum heights are schematic. Both branches start from the same ADC record and starting tick. The residual depends on measured or estimated rejection, and a stored 12 Hz peak can include actual vibration, aliased interference, or both.