Trace Interference Through Decimation

Trace Interference Through Decimation

Try Press Step to follow the 38 Hz test tone into the analog low-pass stage and check where that filter sits relative to the ADC.

Trace Interference Through Decimation

Decimation

Analog low-pass

ADC

Digital low-pass

Decimate

Storage

Input spectrum · schematic

Shaded: wanted band through 20 Hz · Brown: 38 Hz test tone borrowed from the chapter’s motor example.

Vertical position is schematic.

The wanted vibration band extends to 20 Hz. Follow the 38 Hz test tone through the acquisition chain.

Observe With the digital low-pass bypassed, the brown marker is at 38 Hz in the 200 SPS record and at 12 Hz inside the shaded wanted band in the 50 SPS output.
Explain Decimation keeps every fourth sample, lowering the Nyquist limit to 25 Hz. With the digital filter bypassed, any residual 38 Hz tone folds to 12 Hz, inside the band through 20 Hz.

Technical boundaries. The spectrum heights are schematic. Both branches start from the same ADC record and starting tick. The residual depends on measured or estimated rejection, and a stored 12 Hz peak can include actual vibration, aliased interference, or both.