Ten-Year Current Allowance and Uplink Sag

Ten-Year Current Allowance and Uplink Sag

Try Tap Step to expand the uplink and find the duration label below the 45 mA pulse.

Check the reporting cycle

Battery

Ten-minute reporting cycle

Sleep · 1.5 µAUplink marker · schematic
Cycle startsSleep intervalCycle repeats

Follow the reporting cycle

The sensor draws 1.5 µA in sleep and sends an uplink every ten minutes.

Observe The uplink panel reveals a 300 ms pulse, then the current-budget panel marks the 24.0 µA average above the 21.1 µA allowance.
Explain The replay weights sleep and uplink current by their durations in the reporting cycle, giving a 24.0 µA average that exceeds the ten-year allowance.

Technical boundaries. The uplink marker is schematic, and its detail view expands the time scale. The 0.675 V drop across 15 Ω is illustrative. The voltage at the device remains a pending measurement that compares the level just before the pulse with the level during the uplink.

Back to the chapter