Trace a Tap-Water Alarm
Trace a Tap-Water Alarm
Dry probes open the loop
Contact conductivity sensingDry air is effectively an open circuit between these probes, so no current flows around the loop.
Find the gap between the probes and the matching open switch in the schematic.
Pipe and probes
Series circuit
Illustrative wiring
Loop current
I = 3.3 V / (10 kΩ + 2 kΩ) = 0.275 mA
Resistor · 0.275 mA × 10 kΩ = 2.75 V
Wet probes · 0.275 mA × 2 kΩ = 0.55 V
Check · 2.75 V + 0.55 V = 3.3 V
Controller
Input from the junction
Reference wired to supply return
A high-impedance input avoids appreciable loading. It must accommodate the full swing from 0.55 V wet to 3.3 V dry.
Analogue conversion → Threshold decision
Higher input voltage
Dry level
Threshold
Wet level WET
Lower input voltage
Technical boundaries. The circuit represents the wet probes as a fixed 2 kΩ resistance and treats dry air as effectively an open circuit. The controller input is assumed to have high impedance to avoid appreciable loading. Its voltage strip shows the relative levels and leaves the numerical threshold unspecified.