Soil Sensor Model and Bench Charge
Soil Sensor Model and Bench Charge
Compare charge across a complete reporting period
Charge validationFollow the saved model estimate, the prototype trace, and the evidence used to revise the model.
Saved tool run
- Reporting interval · 15 minutes / 900 s
- Active · 8 mA for 2.0 s
- Transmit · 42 mA for 0.8 s
- Sleep · 0.012 mA for 897.2 s
- Saved tool estimate · 1.608 mAh/day from the rounded 0.067 mA average
- Output range · Unspecified in the chapter
- Assumptions · One active and one transmit interval per period, with the remaining time spent in sleep
Bench view · Illustrative trace
Schematic current versus time · Short events expanded.
Measure from the start of a report to the start of the next report.
Save the model inputs and assumptions so you can reproduce the prediction.
Saved tool run
- Reporting interval · 15 minutes / 900 s
- Active · 8 mA for 2.0 s
- Transmit · 42 mA for 0.8 s
- Sleep · 0.012 mA for 897.2 s
- Saved tool estimate · 1.608 mAh/day from the rounded 0.067 mA average
- Output range · Unspecified in the chapter
- Assumptions · One active and one transmit interval per period, with the remaining time spent in sleep
Bench view · Illustrative trace
Schematic current versus time · Short events expanded.
Measure from the start of a report to the start of the next report.
Illustrative trace · Schematic current and time, with short events expanded for visibility.
Model current versus time
Highlighted segments compare radio peak height.
Shorter radio plateau
Bench current versus time
Same schematic current scale as the model
Equal peak · Longer radio plateau
Illustrative trace · Schematic current and time, with short events expanded for visibility.
Model current versus time
Tint covers the area across the full cycle.
Bench current versus time
Same schematic current scale as the model
Equal peak · Longer radio plateau
Charge per reporting period
15 minutes / 900 s · Start of a report to start of the next report
Model ledger · Multiply state current by duration and count repeats over active, transmit, and sleep.
Bench trace · Integrate current over the same reporting window.
Reported chapter example · Charge per 900 s reporting period
Compare the cycle totals in common units.
Tool ledger · Model
- Active · 8 mA × 2.0 s
- Transmit · 42 mA × 0.8 s
- Sleep · 0.012 mA × 897.2 s
Sum · 60.3664 mA·s
60.3664 mA·s ÷ 3,600 s/h ≈ 0.016768 mAh per period
Prototype · Back-calculation
About 1.610 mAh/day ÷ 96 periods/day ≈ 0.01677 mAh per period
Back-calculated from the rounded daily value in the validation figure.
96 periods/day comes from dividing 24 h/day by the 15-minute reporting period.
Daily equivalents and display precision
Rounded model average · 0.067 mA × 24 h/day = 1.608 mAh/day
Prototype in validation figure · About 1.610 mAh/day
The unrounded model ledger also displays as 1.610 mAh/day at the figure’s precision.
Comparison open · Review the full-cycle trace and define an acceptance criterion.
Field log
- Temperature
- Retries
- Missed reports
- Battery voltage
- Charging or harvesting events
Run history
Original input values, assumptions, and output retained.
Field evidence Editable model· Replace supported assumptions with observations
Updated estimate
Re-measure complete cycle
Compare the new estimate and trace over the same reporting period.
Technical boundaries. The current traces are schematic, with short events stretched for visibility. The saved model assumes one active interval and one transmission per report, with sleep filling the rest. The prototype figure is back-calculated from a rounded daily value, and validation still requires the actual trace and an acceptance criterion.