Shaft Motion and Winding Current

Shaft Motion and Winding Current

Try Use Step to move from the controller command to the stationary shaft and find the winding current limit.

Shaft Motion and Winding Current

Back-EMF

Controller, driver and motor

GPIO command Load current Controller Driver External supply Motor

GPIO carries the command. The load-current path uses the external supply.

Motor snapshot

Shaft
Stopped
Opposing voltage
Calculation pending
Winding current
—

Command requests motion

The controller sends the command. The external supply provides the motor’s power through the driver.

Observe The stationary snapshot shows only the supply voltage arrow and a 6 A limit. In the steady running snapshot, an opposing 9 V arrow appears and the current reads 1.5 A.
Explain At rest the shaft generates no back-EMF. Once it turns steadily, 9 V of back-EMF opposes the 12 V supply, reducing the current through the 2 Ω winding to 1.5 A.

Technical boundaries. The comparison assumes a fixed 12 V supply and 2 Ω winding resistance, with 9 V of back-EMF in the settled running example. The startup snapshot gives the limit for a shaft that stays still. Inductance keeps current continuous at switch-on, and the shaft may start turning before that limit is reached.