RFID Cabinet and Portal Tests
RFID Cabinet and Portal Tests
Test every tag shape and position. Include metal, liquid, a crowded cabinet, two tags replying together, a tool just outside the zone, a damaged tag, and a restart. Count expected objects, missed objects, extra objects, and repeated reads. A bench read is not proof of the installed workflow.
Anti-collision allows several tags to share the read zone, but dense populations still need measured performance. Place 100 target tags on real cartons, include nearby non-target tags, and record unique identities, missed targets, and stray reads. A total of 100 messages is not the same as 100 correctly identified cartons because duplicates can hide misses.
Predict the portal evidence. Move one known carton through and expect one application event tied to several raw observations. Reverse direction and expect the opposite event. Hold an object tag at the zone edge and verify whether the reader system rejects or marks it uncertain. Then run the 100-carton load and compare unique expected identifiers with observed ones.
If the reader identifies 100 distinct cartons in 2 s, its observed identification rate is . That RFID reader rate belongs to this object set, orientation, power, and doorway; repeat the calculation with the worst approved packing arrangement.
Technical boundaries. The observed 50 cartons/s rate belongs to the tested object set, orientation, power, and doorway. A total of 100 messages does not establish 100 correctly identified cartons because duplicates can hide misses.