TrySelect Step once and compare the signal trends for Cell A and Cell B at 6 s before looking for the report.
Read an LTE-M handover trace, identify the trigger-to-bearer interval, and distinguish it from a live delivery gap and an after-tuning result.
Mobility
Cell A attached
Radio
Connected to Cell A
Data bearer
The observation starts with the tracker connected.
At T=0 s the tracker is connected to Cell A. The trace begins here.
Cell A ↓ · Cell B ↑
Cell A ↓
Weakening. The tracker still uses Cell A.
Cell B ↑
Strengthening. Signal change is qualitative.
At T=6 s, Cell A weakens and Cell B strengthens.
A3 measurement report
Radio · A3 report
Neighbor met the configured trigger condition.
Baseline rule
Difference greater than 6 dB (4 dB offset + 2 dB hysteresis, with no other offsets) for 480 ms.
At T=9 s the tracker reports that the neighbor met the configured difference and hold-time rule.
Handover command
Radio · Handover command
The modem gets the command while the target association and usable data are still pending in the trace.
The handover command arrives at T=10 s.
Handover complete on Cell B
Radio · Cell B
Handover complete.
Data bearer
Recovery marker still pending.
The radio handover finishes at T=15 s. Follow the data bearer track to see when usable data returns.
Data bearer re-established · bracket starts at A3 report
Data bearer · Re-established
T=18 s − T=9 s = 9 s.
Live delivery gap
The start of the gap was not measured.
Usable data returns at T=18 s. The trigger-to-bearer interval is 9 s, while the trace leaves the live delivery gap unmeasured.
Original event markers retained during route-test review
Proposed A3 offset
4 dB → 2 dB
Hysteresis
2 dB → 1 dB
TimeToTrigger
480 ms → 160 ms
Outcomes to measure
Trigger-to-bearer interval, handover failure rate and live delivery gap. Recovered buffered fixes do not measure the live gap.
The proposed settings change when a report can trigger. Re-run the route and measure each outcome, including any delay after the new cell accepts the tracker.
Start on Cell A
At T=0 s the tracker is connected to Cell A. The trace begins here.
ObserveThe A3 report appears at 9 s, followed by handover complete on Cell B at 15 s. The data bearer still shows recovery pending there and is marked re-established at 18 s.
ExplainThe tracker sends the A3 report when the neighbor meets the configured difference of more than 6 dB for 480 ms. The 9 s interval runs from that report to the return of usable data.
Technical boundaries. The signal trends are qualitative, and the baseline trigger assumes no other offsets. The trace lacks a measured start for the live delivery gap. The final frame keeps the original event markers and lists proposed settings for a future route test.