TryAdvance with Step to the broken F–E link and check which next hop remains installed at D while the update is in transit.
Can D still forward after the relay breaks?
DSDV
Trace the packet decision before and after D receives the invalidation.
Route to G at D · usable
Application probe delivered along D → F → E → G.
Forwarding next hop
Metric
Destination sequence
Status
F
finite
S_old
usable
Latest routing update received at D
Empty
Route to G at D · invalidation in transit
F marks G unreachable and sends the triggered update toward D. D’s update tray remains empty.
Forwarding next hop
Metric
Destination sequence
Status
F
finite
S_old
usable
Latest routing update received at D
Empty
F has marked its own route to G unreachable.
Route to G at D · old next hop still installed
The fresh probe reaches F. No onward route at F.
Forwarding next hop
Metric
Destination sequence
Status
F
finite
S_old
usable
Latest routing update received at D
Empty
Route to G at D · new invalidation installed
D has applied the update and stops forwarding packets for G to F.
Forwarding next hop
Metric
Destination sequence
Status
—
∞
S_break
unreachable
Latest routing update received at D
From F · destination G · metric ∞ · destination sequence S_break > S_old
— means no forwarding next hop.
Route to G at D · next probe blocked
Probe stays at D · no usable route.
Forwarding next hop
Metric
Destination sequence
Status
—
∞
S_break
unreachable
Latest routing update received at D
From F · destination G · metric ∞ · destination sequence S_break > S_old
— means no forwarding next hop.
Before receipt
Sent to F · no onward route
After receipt
No forwarding from D
D’s route to G is already in the table. The application probe travels from D through F and E to G.
ObserveIn Frame 3, the probe reaches F and stops. After D installs the update in Frame 4, the route shows an infinite metric and no next hop, and the next probe stays at D.
ExplainIn Frame 3, D uses its old next hop because the update is still in transit. Once D receives the newer sequence with an infinite metric, it marks G unreachable and stops forwarding to F.
Technical boundaries. The drawing follows a single F–E break and one destination entry at D. Sequence numbers are shown symbolically, and the in-transit frame shows event order without a measured delay. The replay ends with the next probe blocked before any replacement route is accepted.