TryPress Step to widen the measurement from the isolated MCU rail to the whole product and inspect the sleep-current ledger.
Check what the current measurement includes
Power measurements
Identify the selected measurement boundary
Whole product · outside the selected rail
Isolated MCU rail
8 µA in sleep
Regulator
Outside measurement
Standby sensor
Outside measurement
Pull-up leakage
Outside measurement
Extend the scope to the whole product
Whole product · selected measurement
Isolated MCU rail
8 µA in sleep
Regulator
25 µA
Standby sensor
12 µA
Pull-up leakage
6 µA
Sleep-current ledger
Isolated MCU rail
8 µA
Regulator
25 µA
Standby sensor
12 µA
Pull-up leakage
6 µA
Whole-product sleep current
51 µA
Calculate the missing charge
Sleep-current ledger
Isolated MCU rail
8 µA
Regulator
25 µA
Standby sensor
12 µA
Pull-up leakage
6 µA
Whole-product sleep current
51 µA
Bench interval
Sleep current omitted
51 µA − 8 µA = 43 µA
Elapsed time
30 days = 720 h
Convert charge
43 µA × 720 h gives µAh. Divide that value by a thousand to express it in mAh.
Omitted charge over the interval
30.96 mAh
This projection holds the omitted sleep current constant throughout the bench interval.
Inspect the schematic raw transmit trace
Current (mA) · zero reference at the time axis
Time → · One-second meter window · 200 ms burst · 120 mA total current at the peak
Charge from raw trace
The shaded area is the total charge above zero during the window. The local baseline has no numeric label.
Compare the exact window mean
Current (mA) · zero reference at the time axis
Time → · One-second meter window · 200 ms burst · 120 mA total current at the peak
Charge over the same window
Charge from raw trace
Area above zero under the rectangular burst and local baseline
Charge from window mean
Area above zero under the meter reading. This area equals the raw-trace area.
Schematic reference
Dashed raw trace
Meter reading
Baseline + (peak − baseline) × burst duration ÷ window duration. Use matching time units.
Close the measurement record
Current (mA) · zero reference at the time axis
Time → · One-second meter window · 200 ms burst · 120 mA total current at the peak
Charge over the same window
Charge from raw trace
Area above zero under the rectangular burst and local baseline
Charge from window mean
Area above zero under the meter reading. This area equals the raw-trace area.
Schematic reference
Dashed raw trace
Meter reading
Baseline + (peak − baseline) × burst duration ÷ window duration. Use matching time units.
Sleep-current ledger
Isolated MCU rail
8 µA
Regulator
25 µA
Standby sensor
12 µA
Pull-up leakage
6 µA
Whole-product sleep current
51 µA
Verify the measurement on the bench
Check whole-product scope and whether the measurement setup changes operation. Select bandwidth and range for peaks and sleep leakage. Align captures with firmware markers. Capture through the tail to the intended sleep baseline and include rare events.
A sleep reading only covers the loads inside the selected measurement boundary.
ObserveThe ledger grows from an 8 µA rail reading to a 51 µA whole-product total, and the bench interval panel shows 30.96 mAh of omitted charge.
ExplainThe isolated rail leaves out the regulator, standby sensor and pull-up leakage. The charge projection holds their combined 43 µA constant for 720 h.
Technical boundaries. The sleep-charge calculation assumes a constant omitted current throughout the bench interval. The transmit chart uses a schematic rectangular burst and leaves its local baseline unlabeled. Its exact window mean preserves the depicted charge while hiding the burst peak and duration.