Meter Access-to-Uplink Finish
Meter Access-to-Uplink Finish
Compare two intervals on the same meter trace
NB-IoT accessWake and cell acquisition
- 12:00:00.000 · Meter wake
Basement meter
Wake at 12:00:00.000
Serving cell · untimed broadcasts
NPSS / NSSS for synchronization
NPBCH carries MIB-NB. Subsequent SIB-NB arrives on NPDSCH.
Random access starts
- 12:00:00.000 · Meter wake
- 12:00:00.400 · Meter → cell: NPRACH access preamble
NPRACH request signal
Meter → serving cell
Possible access behavior
The cell configures preamble repetitions and hopping. Collisions can lead to backoff before the next attempt.
Access response
- 12:00:00.000 · Meter wake
- 12:00:00.400 · Meter → cell: NPRACH access preamble
- 12:00:00.780 · Cell → meter: access response
Serving cell → meter
Access response observed
Scheduled grant
Separate observation, still to come
Grant monitoring may require listening.
Scheduled grant
- 12:00:00.000 · Meter wake
- 12:00:00.400 · Meter → cell: NPRACH access preamble
- 12:00:00.780 · Cell → meter: access response
- 12:00:01.050 · Cell → meter: NPDCCH scheduled uplink grant
Timing
Value unreported in this trace
Tones
Value unreported in this trace
Modulation and coding
Value unreported in this trace
Repetitions
Value unreported in this trace
Uplink finish · choose the interval
- 12:00:00.000 · Meter wake
- 12:00:00.400 · Meter → cell: NPRACH access preamble
- 12:00:00.780 · Cell → meter: access response
- 12:00:01.050 · Cell → meter: NPDCCH scheduled uplink grant
- 12:00:01.420 · NPUSCH uplink finish
Meter → cell
Uplink start and airtime unreported
Possible transfer behavior
Configured repetitions during transfer. Failure may trigger retransmissions.
Compare both intervals
- 12:00:00.000 · Meter wake
- 12:00:00.400 · Meter → cell: NPRACH access preamble
- 12:00:00.780 · Cell → meter: access response
- 12:00:01.050 · Cell → meter: NPDCCH scheduled uplink grant
- 12:00:01.420 · NPUSCH uplink finish
Access start to uplink finish
1.420 − 0.400 = 1.020 s
Wake to uplink finish
1.420 s
The hatched wake-only segment includes initial cell search and broadcast reading.
The uplink finished, but the cloud shows no reading. What would you inspect?
Evidence to close the transaction
- 12:00:00.000 · Meter wake
- 12:00:00.400 · Meter → cell: NPRACH access preamble
- 12:00:00.780 · Cell → meter: access response
- 12:00:01.050 · Cell → meter: NPDCCH scheduled uplink grant
- 12:00:01.420 · NPUSCH uplink finish
Radio downlink
Record any observed NPDSCH downlink separately.
Application receipt
Inspect routing and look up receipt by packet identity.
Delivery evidence needed; application acceptance open.
Application acknowledgement
Look for it where the deployed service uses one.
Current trace
Follow wake through the applicable final power state.
The basement meter wakes, listens for cell timing, and reads broadcast information so it knows how to request a turn.
Technical boundaries. The ruler times selected events on one basement meter trace. It leaves the broadcast events untimed and gives no uplink start time or airtime. The finish marker records radio transmission completion. Application delivery still needs a receipt matched by packet identity.