Task Lamp Hysteresis

Task Lamp Hysteresis

Try Select Step from the starting 40 lux reading and watch the lamp as the next scripted sample arrives.

Predict the lamp’s next state

Hysteresis
Task lamp · OFF

Scripted incident illuminance

40 lux
  • Turn ONBelow 35 lux
  • Hold state35–45 lux inclusive
  • Turn OFFAbove 45 lux
Previous state
OFF
Comparison
Inside hold band
Resulting state
OFF

Start inside the band

The lamp starts OFF. At 40 lux the reading is inside the band, so it stays OFF.

Observe At 28 lux the lamp turns ON. The readout returns to 40 lux and the lamp stays ON, then a later return to 40 lux shows the lamp OFF.
Explain The band from 35 to 45 lux includes both endpoints and preserves the previous lamp state, so 40 lux can keep the lamp either ON or OFF.

Technical boundaries. Scripted readings drive the lamp, and the replay begins with the lamp OFF. When the reading goes above 45 lux, the scale indicates an open-ended region and the sample pointer disappears because that frame supplies no exact reading.