Read a qualification or HALT result
Read a qualification or HALT result
Try Press Step once to reveal the first qualification run and locate the exposure marker on the device rating strip.
Read a qualification or HALT result
Environmental testIllustrated exposure relative to the device ratingWithin rated conditionsBeyond rated conditions
Rating for this condition divides the stripSchematicSchematic
Run purpose
- Choose the review question
Monitored function
- Maintain sensor calibration during exposure
- Tested sealed assembly · operating during exposure
Illustrated exposure relative to the device ratingWithin rated conditionsBeyond rated conditions
Rating for this condition divides the stripObserved exposure—
Qualification example with calibration held
- Tested sealed assembly · operating during exposure
- Within rated conditions · maintain sensor calibration during exposure
- Calibration held → requirement met at tested condition
Illustrated exposure relative to the device ratingWithin rated conditionsBeyond rated conditions
Rating for this condition divides the stripObserved exposure—
Qualification example with calibration held
- Tested sealed assembly · operating during exposure
- Within rated conditions · maintain sensor calibration during exposure
- Calibration held → requirement met at tested condition
Qualification example with calibration lost
- Separate run · tested sealed assembly operating during exposure
- Within rated conditions · maintain sensor calibration during exposure
- Calibration lost → requirement failed at tested condition
Illustrated exposure relative to the device ratingWithin rated conditionsBeyond rated conditions
Rating for this condition divides the stripEarlier separate runsObserved exposure
Qualification example with calibration held
- Tested sealed assembly · operating during exposure
- Within rated conditions · maintain sensor calibration during exposure
- Calibration held → requirement met at tested condition
Qualification example with calibration lost
- Separate run · tested sealed assembly operating during exposure
- Within rated conditions · maintain sensor calibration during exposure
- Calibration lost → requirement failed at tested condition
HALT · Highly accelerated life testing
- Search for weak points and margin
- Calibration lost → weak point observed beyond the rating
- Investigate the weak point and margin
Illustrated exposure relative to the device ratingWithin rated conditionsBeyond rated conditions
Rating for this condition divides the stripPinned qualification evidencePinned HALT observation
Within rated conditions
Qualification example with calibration held
- Tested sealed assembly · operating during exposure
- Within rated conditions · maintain sensor calibration during exposure
- Calibration held → requirement met at tested condition
Qualification example with calibration lost
- Separate run · tested sealed assembly operating during exposure
- Within rated conditions · maintain sensor calibration during exposure
- Calibration lost → requirement failed at tested condition
Beyond rated conditions
HALT · Highly accelerated life testing
- Search for weak points and margin
- Calibration lost → weak point observed beyond the rating
- Investigate the weak point and margin
HASS · Highly accelerated stress screening
Screen for latent defects that could cause early-life failures.
Accelerated stress
✕ Latent defect flagged
Record · Screening result
Illustrated exposure relative to the device ratingWithin rated conditionsBeyond rated conditions
Rating for this condition divides the stripQualification evidenceHALT weak-point evidence
Within rated conditions
Qualification example with calibration held
- Tested sealed assembly · operating during exposure
- Within rated conditions · maintain sensor calibration during exposure
- Calibration held → requirement met at tested condition
Qualification example with calibration lost
- Separate run · tested sealed assembly operating during exposure
- Within rated conditions · maintain sensor calibration during exposure
- Calibration lost → requirement failed at tested condition
Beyond rated conditions
HALT · Highly accelerated life testing
- Search for weak points and margin
- Calibration lost → weak point observed beyond the rating
- Investigate the weak point and margin
HASS · Highly accelerated stress screening
Screen for latent defects that could cause early-life failures.
Accelerated stress
✕ Latent defect flagged
Record · Screening result
Illustrative outcomes
Start with the device rating and the question the run needs to answer.
Observe In frame 3, the within-rating qualification card shows Calibration lost and requirement failed. In frame 4, the selected exposure lies beyond the rating and the HALT card records a weak point.
Explain In frame 3, calibration loss fails the requirement because the assembly must maintain calibration while operating within its rating. Frame 4 uses the same symptom to identify a weak point beyond the rating.
Technical boundaries. The chamber and rating strip are schematic, with exposure shown relative to the rating for the condition. The qualification cards represent separate runs on an operating sealed assembly, and each outcome applies to the calibration requirement at the tested condition.