Slow Humidity Response or Stale Data?

Slow Humidity Response or Stale Data?

Try Choose Step to compare the overlapping baseline traces for outdoor relative humidity and the sheltered probe before the air changes.

Slow Humidity Response or Stale Data?

Relative humidity

Outdoor air

Change to test
Known sustained step in relative humidity

Probe inside the shelter

Enclosure wall
Condensation droplet
Airflow → probe
Restricted opening

Dashboard

Relative humidity trend
Steady ─────
Test question
What will the dashboard show when the outside air changes?

Predict the dashboard response

After the move, the dashboard is steady. Use a known change in the air to test whether the probe can still track it.

Observe In frame 3 the display uses the late square while the probe trace rises behind the reference. In frame 4 the square still marks a newer capture, but the redrawn display returns to the earlier circled value and time.
Explain Frame 4 exposes a stale display because its original capture time repeats while acquisition continues. The faster probe response after the ventilation change shows that the enclosure contributed to the delay under the test conditions.

Technical boundaries. The plots show relative humidity and time without numeric scales. The comparison holds temperature steady and matches starting humidity, reference, probe and acquisition settings. It changes only ventilation, and calibration calls for a separate comparison after the readings settle.